KEYPAD CONTROLS & INDICATORS
1Window. Displays system status messages, zone descriptions, etc.
2STATUS Light. Lights (green) to indicate that the system is ready for arming. If a zone is not secured the light will be off and the zone will display in the window. If a zone has been bypassed, the STATUS light will blink while armed.
3ARMED Light. Lights (red) to indicate that the system is armed. If an alarm has occurred, the ARMED LED will be flashing.
4FUNCTION Button. Selects available system functions as displayed in the window. The selected function is executed by pressing the J button.
5BYPASS Button. (1) Deactivates selected zones from the system.
(2) Unbypasses a bypassed zone
6RESET Button. (1) Resets various system troubles, displays, etc. (See text.) (2) Resets residential smoke detectors.
7Numerical Keys
8ON/OFF Button. Entry key. Causes the entered code or selected function to be executed.
9INTERIOR Button. (1) Bypasses all Interior Zones simultaneously to allow free movement within the premises. (2) Scrolls the window display forward (NEXT). (3) Answers “YES” to questions in the window display.
10INSTANT Button. (1) Cancels entry delay on Exit/Entry Zones, causing an instant alarm upon violation. (2) Scrolls window display backward (PRIOR). (3) Answers “NO” to questions in the window display.
11AREA Button (*). Selects other areas and is used with emergency buttons.
12Emergency Buttons. Used with the G button to signal an emergency, as follows:
Press the 7 and the G
buttons for Fire Emergency.
Press the 8 and the G
buttons for Auxiliary Emergency.
Press the 9 and the G
buttons for Police Emergency.
5