OPTIONAL FAN INSTALLATION

11

OPTIONAL FAN INSTALLATION

ELECTRICAL INSTALLATION TO BE DONE BY A QUALI- FIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

FIGURE 26

The wire harness provided in this kit is a universal har- ness. When installed, ensure that any excess wire is con- tained, preventing it from making contact with moving or hot objects.

OPEN ENDED SLOTS

OPTIONAL THERMOSTATIC

FIGURE 27

SENSOR

 

RECEPTACLE /

THERMOSTATIC SENSOR CONTROLManual background JUNCTION BOX

VARIABLE SPEED/

PIEZO IGNITOR BRACKET

Position the vibration reducing pad into the clip and onto the threaded stud at the other end, piercing a hole into the pad. The fan assembly must be able to be positioned en- tirely onto the pad.

Slide the fan assembly past the controls and and into the clip. Secure using the lock washer and nut provided.

Plug the harness cord connectors onto the connections of the fan as illustrated. Plug the power cord into the recepta- cle.

THERMOSTATIC SENSOR CONTROL

This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, shown above, which may be ordered from your Wolf Steel / Napoleon dealer.

With the thermostatic sensor option, the fan, when turned on, becomes thermally activated, and will automatically run approximately 10 minutes after the fireplace has been lit and for approximately 30-45 minutes after the fireplace has been turned off.

Use of the fan increases the output of heat.

Unplug the power cord from the receptacle. Connect all wires as shown.

Attach and secure the sensor assembly bracket to the se- curing stud located next to the receptacle/junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.

Plug the power cord back into the receptacle.

When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot ob- jects.

THERMODISC Manual background

FIGURE 29

SENSOR ASSEMBLY

BRACKET

Manual background RECEPTACLE /

JUNCTION BOX

FIGURE 28