Napoleon Fireplaces EF34H, EF36H Mantel, Clearance To Combustibles, Framing And Finishing

Models: EF36H EF34H

1 12
Download 12 pages 32.12 Kb
Page 6
Image 6
FINISHING

6

FINISHING

MANTEL

The minimum distance from the top of the unit that the mantel can be installed is 0", at any depth.

When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant to prevent discolouration.

CLEARANCE TO COMBUSTIBLES

 

Sides

0 inches

 

 

 

 

Back

0 inches

 

 

Floor

0 inches

 

 

Top

0 inches

 

 

 

 

 

FRAMING AND FINISHING

Nailing

Tab

Installation

Sheet

Metal

Screw

1.Choose fireplace location.

2.Place fireplace in position.

3.Frame in fireplace with header across the top. It is impor- tant to allow for the finished facing materials when setting the depth of the frame.

4.Remove the two screws from the sides of the fire- place and attach the nail- ing tabs with the screws.

5.To determine the final location of the nailing tab,

you must first determine the thickness of your fin- ishing material (i.e.

sheetrock/drywall) This will determine the dimension from the control panel front edge to the nailing tab. Secure with a sheet metal screw supplied.

6.Attach the nailing tabs to the frame.

W415-0405 / B / 03.25.04

Page 6
Image 6
Napoleon Fireplaces EF34H, EF36H manual Mantel, Clearance To Combustibles, Framing And Finishing