6
W415-0496 / B / 08.10.05
MAINTAIN THESE MINIMUM CLEARANCES TO
COMBUSTIBLES:
A. 4" B. 2"*C. 2"
STOVE SHOULD NOT BE INSTALLED DIRECTLY ON CARPETING.
MINIMUM 48" FROM STOVE TOP TO CEILING
TO CEILING FROM STOVE TOP.......................................48"
HORIZONTAL VENT
SIDES AND BOTTOM .....................................................1"
TOP............................................................................2"
VERTICAL VENT
ALL SIDES.............. .....................................................1"
If less than 5" clearance is maintained between the back
of the stove and the back wall, it will be necessary to
disconnect the venting and gas pipe to move the stove
out for installation or service of the blower.

Provide adequate accessibility clearance for servicing

and operating the stove.

Never obstruct the front opening of the stove.

As long as clearance to combustibles is kept within the
required distances, the most desirable and beneficial lo-
cation for a Napoleon stove is in the centre of a building,
thereby allowing the most efficient use of the heat created.
The location of windows, doors and the traffic flow in the
room where the stove is to be located should be consid-
ered. If possible, you should choose a location where the
vent will pass through the house without cutting a floor or
roof joist.
FIGURE 2
LOCATION & CLEARANCES

GDS20

FIGURE 1
PILOT INDICATORLIGHT BATTERYREPLACEMENT
If the pilot indicator light no longer flashes and the pilot is
burning, the batteries may require replacing.
Four "AA" batteries are required and should be replaced
annually.
1. Open the switch housing by removing the top screw,
then pivoting the box open.
2. Remove the 4 "AA" batteries and replace using the new
ones.
3. Pivot the box closed and re-secure using the screw
removed in step 1.
*AT A DISTANCE OF 2" FROM THE WALL, INSTALLATION OR SERV-
ICE TO THE BLOWER MAY NOT BE PRACTICAL. A MINIMUM OF 5"
WILL BE REQUIRED IN ORDER TO INSTALL THE BLOWER.