Napoleon Fireplaces GDS25N Typical Vent Installations, Special Vent Installations, FIGURES 3 a-c

Models: GDS25N GDS25P

1 28
Download 28 pages 61.26 Kb
Page 10
Image 10
TYPICAL VENT INSTALLATIONS

10

TYPICAL VENT INSTALLATIONS

NOTE:

When terminating vertically above 15', the restrictor plate must be in the fully closed po- sition. Refer to Restricting Vertical Vents.

FIGURES 3 a-c

16"

40FT

MAX

3FT

MIN

SPECIAL VENT INSTALLATIONS

PERISCOPE TERMINATION

Use the GD201 periscope kit to locate the air termination

 

above grade. The periscope must be installed so that when

 

final grading is completed, the bottom air slot is located a

 

minimum of 12 inches above grade. The maximum allowable

 

vent length depends on the fireplace, as illustrated.

24" MINIMUM

 

REGARDLESS

 

OF HORIZONTAL

 

VENT LENGTH

12"MINIMUM

FIGURE 4

BELOW GRADE INSTALLATION MAXIMUM 10FT VENT LENGTH USE GD201 PERISCOPE KIT

W415-0547 / C / 07.25.06

Page 10
Image 10
Napoleon Fireplaces GDS25N Typical Vent Installations, Special Vent Installations, Periscope Termination, FIGURES 3 a-c