opening and the area surrounding the logs clean by vacuum- ing or brushing, at least once a year.
3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly. Take care not to enlarge these parts.
4. Check to see that the pilot fl ames are large enough to engulf the thermocouple and the thermopile on one leg and reaches toward the burner on the other leg.
5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5-10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer/distributor.
ORIFICE REPLACEMENT

11

ADJUSTMENTS

MAINTENANCE

TURN OFF THE GAS AND UNPLUG ELEC-

TRICAL POWER BEFORE SERVICING THE

STOVE!

CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This stove should be inspected before use and at least annually by a qualifi ed service person. The fi replace area must be kept clear and free of combustible materials, gasoline or other fl ammable vapours and liquids.

1. In order to properly clean the burner and pilot assembly, remove the logs exposing both assemblies.

2. Keep the control compartment, logs, burner, air shutter

VENTURI ADJUSTMENT

1. In order to properly clean the burner and pilot assembly, remove the logs exposing both assemblies.

2. Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuum- ing or brushing, at least once a year.

Air shutter adjustment must only be done by a

qualified gas installer!

Closing the air shutter will cause a more yellow flame, but can lead to carboning. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.

1.Remove the cast front and the screen, see Cast Front and Screen

Removal in the FINISHING section of this manual.

2.Remove the 2 securing screws indicated and remove the burner assembly.

3. The orifi ce is located on the left

ORIFICE

hand side.

LOCATION

 

4. Reinstall the burner ensuring that

BURNER

the venturi tube fi ts over the orifi ce

ASSEMBLY

and replace the screws.

SCREW

 

LOCATIONS

Care should be taken not to damage

the gas pipe. When removing and replacing the orifi ce, using a 9/16" socket wrench, a 7/8" back-up wrench must be used on the manifold, located below the housing, to ensure that the aluminium tubing does not twist or kink.

OXYGEN DEPLETION SENSOR PILOT

CLEANING

This procedure must be performed by

a qualified service person!

Inspect the pilot for any visible contamination or debris (usually lint, pet hair, spider webs, carpet fi bre, etc.) and remove.

Disconnect the pilot from the pilot tubing line. Using a 7/16” wrench, remove the injector from the pilot housing. Blow out the housing in the same direction as the gas fl ow.

Re-install the injector and the pilot tube, turn on the gas and check for leaks.

If this does not improve the performance, replace the pilot with an exact replacement. The device is tamper resistant with no fi eld serviceable parts.

CORRECT PILOT

INCORRECT PILOT

FLAME

FLAME

W415-0559 / 02.15.06

Page 11
Image 11
Napoleon Fireplaces GVFS20P, GVFS20N manual Adjustments, Venturi Adjustment, Oxygen Depletion Sensor Pilot Cleaning

GVFS20P, GVFS20N specifications

The Napoleon Fireplaces GVFS20P and GVFS20N gas fireplaces are elegant and functional additions to any living space, offering a blend of modern technology and classic aesthetics. These versatile units are designed to enhance the ambience of your home while delivering efficient heating solutions.

One of the standout features of the GVFS20P and GVFS20N is their customizable design. Available in both propane and natural gas models, these fireplaces allow homeowners to select the fuel type that best suits their needs. This adaptability makes them a popular choice among consumers looking for flexibility in their heating options.

The GVFS series boasts a compact design, making it suitable for various living spaces, including smaller rooms that may not accommodate traditional fireplaces. With a viewing area that maximizes flame exposure, these models elegantly showcase the dancing flames, creating a cozy atmosphere.

Equipped with Napoleon's patented PHAZER log set and glowing ember bed, the GVFS20P and GVFS20N replicate the natural look of a wood-burning fireplace. The realistic flames, combined with the realistic log set, provide a stunning visual experience while ensuring efficient heat production. Moreover, the inclusion of a tempered glass front helps prevent heat loss, allowing for optimal energy efficiency.

The GVFS models are also equipped with advanced technology features, including a Bluetooth-enabled remote control that allows users to adjust the flame height and heat output from the comfort of their seating area. This user-friendly interface maximizes convenience, enabling you to create the perfect ambiance with just a few clicks.

Another key characteristic of these fireplaces is the patented firebox design that enhances combustion efficiency while reducing exhaust emissions. This technology ensures that both models meet strict environmental standards while delivering impressive heating performance. The GVFS20P and GVFS20N also come with safety features, including an automatic shut-off system that contributes to peace of mind for users.

In summary, the Napoleon Fireplaces GVFS20P and GVFS20N stand out in the market for their aesthetic appeal, advanced technologies, and user-friendly features. With their beautiful flame display, customizable options, and commitment to efficiency and safety, they represent a superb choice for anyone looking to enhance their home with a modern gas fireplace solution. Whether you prioritize design, functionality, or environmental responsibility, these models deliver on all fronts, making them a worthwhile investment for any cozy living space.