7
BLOWER INSTALLATION
Blower (SEE LOCATION AND CLEARANCES IN INSTRUCTION MANUAL)
1.Cut and remove the tie securing the blower switch wires to the heat shield.
2.Connect the white wire coming from below the unit to the terminal on the blower.
3.Connect the black blower wire to the black wire coming from below the unit.
4.Insert the clips on the blower housing into the cutouts in the rear shield. Push down to lock the clips into position.
5.Secure the blower using the screw and lock washer sup- plied.
Note: Ensure that all the wires are tucked into the blower switch housing.
7 | 7 | 9 |
| ||
|
|
8
Switches
6. Open the switch housing by removing the top screw. | |||
7. With the 2 screws | THERMODISC | ||
and extension bracket | |||
BRACKET | |||
supplied | in the unit |
| |
baggie, fasten extension |
| ||
bracket to the thermodisc |
| ||
bracket. | Install bracket |
|
assembly as shown, using |
| |
2 of the screws supplied. | THERMODISC | |
Connect the fl agged leads | ||
EXTENSION | ||
to the terminals of the | ||
BRACKET | ||
thermodisc. | ||
|
8.Remove the knock out from the switch housing label. Install the variable speed switch (rheostat) into the housing with the wires facing up. Secure the switch to the housing using the pal nut and the knob supplied.
9.Connect the male connector on the switch to the female connector coming from the unit.
10.Pilot Indicator Light: Install the batteries as shown. Replace the batteries annually. Note: If replacing the pilot indicator light , ensure that the red wire lead connects to the red lead of the thermopile and black to white.
11.Tuck all of the wires into the switch housing and close. Secure using the screw removed in step 6.
7 | 7 | 9 |
| ||
|
|
1 | 4 |
|
|
| 4 |
|
|
This unit comes equipped | 2 |
|
|
|
|
| |
with a pilot indicator light 3 | 8 | ||
that blinks every few | |||
seconds when the pilot | 5 |
|
|
is on. |
|
| |
|
| ||
|
|
|
For more information see
step #10.
GAS INSTALLATION
1.Install rigid black pipe, or 1/2" type L copper tubing with a
2.Seal and tighten the gas line securely to a fl ex connector.
DO NOT KINK FLEXIBLE CONNECTOR.
For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient loca- tion. Route 2 strand solid core millivolt wire from the gas stove to the wall switch / millivolt thermostat. The recom-
3/8NPT
ADAPTER FITTING
1
2TPTH
TP TH
3
TOLIP
FLEXIBLE |
|
| SHUT OFF | |
| CONNECTOR | VALVE | ||
|
|
|
| 1/2FPT |
|
|
|
| BLACK |
|
|
|
| PIPE |
|
|
| 3. Check for gas leaks by | |
OL |
|
| brushing on a soap and | |
| N | O | ||
| F | water solution. Do not use | ||
HI | O | F | ||
| TOL |
| ||
| IP |
|
|
open fl ame.
mended maximum lead length depends on the wire size:
wire sizemax. length |
|
14gauge | 100 feet |
16gauge | 60 feet |
18gauge | 40 feet |
Disconnect the existing wires from terminals 1 and 3 (from the on/off switch) and replace with the leads from the wall switch/millivolt thermostat.