Napoleon Fireplaces GVFS60-N General Instructions, Shipping Bracket, Mobile Home Installation

Models: GVFS60-P GVFS60-N

1 16
Download 16 pages 62.3 Kb
Page 4
Image 4
GENERAL INSTRUCTIONS

4

GENERAL INSTRUCTIONS

THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the GVFS60 to the current National Fuel Gas Code, ANSI Z223.1 In- stallation Code which can be obtained from:

American Nation Standards Institute Inc.

1430 Broadway

New York, NY 10018

or

National Fire Protection Association Inc.

Batterymarch Park

Quincy, MA 02269

The fireplace and its individual shutoff valve must be dis- connected from the gas supply piping system during any pressure testing of that system at test pressures in ex- cess of ½ psig (3.5 kPa). The fireplace must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5 kPa).

The stove, when installed with a blower, must be electri- cally connected and grounded in accordance with local codes. In the absence of local codes, use the current ANSI/NFPA 70-1996 NATIONAL ELECTRICAL CODE. The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug.

SHIPPING BRACKET

To avoid the stove being damaged during shipping, a ship- ping bracket has been used and must be unbolted before the stove can be installed.

1.Remove the four nuts holding the shipping bracket to the bottom of the stove.

2.Lift the stove up and away from the skid to clear the threaded bolts sticking through the bracket. Set down on a flat surface. The stove top is not secured to the unit.

3.Discard the nuts, bracket and the skid.

4 NUTS

S H I P P I N G

BRACKET

FIGURE 1

MOBILE HOME INSTALLATION

Suitable for mobile home installation where the mobile home has been permanently placed on its site.

This fireplace may be installed in an aftermarket per- manently located, manufactured (mobile) home, where

not prohibited by local codes.

For mobile home installations, the fireplace must be fas- tened in place. It is recommended that the fireplace be secured in all installations. Use the levelling / securing kit, GDSLL-KT, for this purpose.

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUAL- ITY! Maximum input is 30,000 BTU/hr for natural gas and propane. When the fireplace is installed at elevations above 2,000ft, and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft.

This heater must not be installed in a bedroom or bath- room.

This fireplace is only for use with the type of gas indi- cated on the rating plate. This fireplace is not convert- ible for use with other gases, unless a certified kit is

used.

Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane.

No external electricity (110 volts or 24 volts) is required for the gas system operation. Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.

This heater is equipped with a pilot light safety system referred to as an OXYGEN DEPLETION SENSOR and is designed to turn off the heater if not enough fresh air is available.

Use only accessories designed for and listed

with your specific fireplace.

CARBON MONOXIDE POISONING

MAY LEAD TO DEATH

Early signs of carbon monoxide poisoning re- semble the flu, with headache, dizziness and/ or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced.

Some people---pregnant women, persons with heart or lung disease, anemia, those un- der the influence of alcohol, those at high alti- tudes--- are more affected by carbon monox- ide than others.

W415-0204 / C / 10.02.01

Page 4
Image 4
Napoleon Fireplaces GVFS60-N manual General Instructions, Shipping Bracket, Mobile Home Installation, General Information