TROUBLE SHOOTING

SYMPTOM

PROBLEM

TEST SOLUTION

 

 

 

 

 

Flames extinguish during lighting.

Very cold chimney. No draft

- Leave door ajar until fire has caught.

 

established

- check air supply in the room

 

 

 

 

Fire extinguishes once firestarter has

Fuel tank is empty

- Fill tank

burnt off.

 

 

 

Fuel valve is closed.

- Open valve

 

 

 

 

 

 

Main carburetor float not engaging.

- De-press the safety lever

 

 

 

 

 

Control knob is set on “0"

- Adjust control knob to ”1"

 

 

 

 

Fire extinguishes during use.

Fuel tank is empty.

- Fill tank

 

 

 

 

 

Insufficiant draft

- Call your installer

 

 

 

 

Flame is excessely large, smokey and

Fuel adjustment made too quickly.

- Return control knob to “1" ; wait for

sooty.

 

normal combustion. (catalyser should

 

 

glow red).

 

 

- Wait 5 to 15 minutes between each

 

 

adjustment.

 

 

 

 

Stove burns noisily, extinguishes and

Burner contains excess fuel

- Adjust to lower setting. If problem

relights itself.

 

persists call your installer.

 

 

 

 

 

Insufficient fuel

- Check that the de-scaler, the

 

 

carburetor filter and burner pot are

 

 

cleaned.

 

 

 

 

Fire smokes.Soot build up noticed.

Insufficient air supply.

- Increase fresh air supply (open door,

Flame imbalance

 

window ; add make up air supply)

 

 

 

 

 

Downdraft or blockage in chimney

- Check Chimney for Soot build up.

 

 

clean if necessary.

 

 

- Ensure chimney height is sufficient

 

 

and cap is not affected by any nearby

 

 

obstructions.

 

 

- Room is in negative pressure.

 

 

Increase fresh air supply. Check draft

 

 

with draft meter and adjust if not to

 

 

requirements. See page 5.

 

 

 

 

 

Oil flow is too low on 1 setting.

- Adjust low flow rate while control is

 

 

set on “1", call your installer.

 

 

 

 

 

Stove is not level. Flame imbalance.

Check level. Adjust if necessary.

 

 

 

 

 

Catalyser not centered. Uneven fuel

Center catalyser assembly

 

distribution resulting in secondary air

 

 

 

shortage.

 

 

 

 

 

 

 

Insufficient fuel

- Check that the de-scaler, the

 

 

carburetor filter and burner pot are

 

 

cleaned.

 

 

 

15/01/2002~1-1043n°

Coke build up noticed.

Excessive air supply.

 

- Adjust draft.

 