OPERATION

CAUTION : AVOID INHALING FUMES EMITTED FROM THE HEATER'S FIRST USE. SMOKE AND ODOR FROM THE BURNING OF OILS USED IN MANUFACTURING WILL APPEAR. BOTH SMOKE AND ODOR WILL DISSIPATE AFTER APPROXIMATELY 30 MINUTES. THE HEATER SHOULD NOT PRODUCE THICK BLACK SMOKE.

NOTE:

The burner may be noisy when initially turned on. To eliminate excessive noise from the burner, turn the Control Knob to the "LOW" position. Then, turn the knob to the level of heater desired.

When heater is ON:

Emitter screen will become bright red due to intense heat. The color is more visible at night. Burner will display tongues of blue flame. These flames should not be yellow or produce thick black smoke, indicating an obstruction of airflow through the burners.

Operation pressure checked:

If the flame is very small, this is because the supply pressure is not enough. Please refill gas cylinder.

Re-light:

1)Turn the control knob to "OFF" position.

2)Wait five (5) minutes before attempting to relight pilot.

3)Repeat steps beginning with step 4 of the lighting instruction above.

Shut down instructions:

1)Push in and turn control knob clockwise to "OFF" position.

2)Turn clockwise to disconnect cylinder from regulator when heater is not in use.

Note: After use, some discoloration of the emitter screen is normal.

The Event of Gas Leakage:

1) Turn the control knob to "OFF" position.

2) Turn clockwise to disconnect cylinder from regulator.

3) Wait 5 minutes to allow gas to dissipate.

4) If odor continues, immediately call gas supplier.

WARNING : Heater will be hot after use.

Handle with extreme care.