Napoleon Fireplaces ZCVF42 installation instructions ZCVF36, Framing

Models: ZCVF42 ZCVF36

1 12
Download 12 pages 27.75 Kb
Page 6
Image 6
FRAMING

6

FRAMING

ANY CHANGE TO THIS ENCLOSURE CAN BE DANGEROUS AND IS PROHIBITED.

It is best to frame your ventless firebox enclosure after it is positioned. Use 2x4’s and frame to local building codes.

(FIGURE 3-5)

ZCVF36

ZCVF42

FIGURE 3

 

 

 

 

 

3

2 3/4

"

35 3/4"

211/4"

FIGURE 4

42

1/2”

 

211/4"

47

1/8”

 

52 1/3”

FIGURE 5

OUTSIDE

CHASE

 

55 5/8”

42 1/2”

47 1/8”

74 1/8”

78 5/8”

 

OUTSIDE

 

21 1/4"

CHASE

21 1/4"

 

42 1/2"

47 1/8"

21 1/4”

INSIDE

CHASE

42 1/2” (FIGURE 3-5)Manual backgroundManual background 6"

21 1/4”

INSIDE

CHASE

47 1/8” Manual backgroundManual backgroundManual background 6"

Minimum clearance to combustible construction from ventless firebox enclosure:

sides, back, bottom and top of the unit

0 inches

recessed depth

21 1/4 inches

Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the ventless firebox

enclosure body, it is recommended that the walls of the ventless firebox enclosure enclosure be “finished” (ie: drywall/sheet- rock), as you would finish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.

When roughing in the ventless firebox enclosure, raise the ventless firebox enclosure to accommodate for the thickness of the finished floor materials, i.e. tile, carpeting, hard wood.

Objects placed in front of the ventless firebox enclosure should be kept a minimum of 4 feet away from the front face.

W415-0527 / 09.29.05