Napoleon Fireplaces ZCVF36 With Thermal Switch Bracket, Blower, Thermal Disc, Variable, Speed

Models: ZCVF42 ZCVF36

1 12
Download 12 pages 27.75 Kb
Page 9
Image 9
WITH THERMAL SWITCH BRACKET

9

Note: In either application it is necessary to remove the variable speed switch from the wiring harness and install into an electrical switch box as per electrical codes.

WITH THERMAL SWITCH BRACKET

1.Remove the hearth pads and the blower access cover. (FIGURE 9)

2.Install the blower using the optional blower installation instructions.

3.Pull the black and white thermal disc wires through the 7/8” bushing in the blower access cover.

4.Cut the white wire as close to the connector as possible. (FIGURE 11).

5.Cut the red wire as close to the plug as possible. (FIGURE 11)

6.Using a box connector, connect supply wire through the junction cover plate located on the right sidce of the firebox enclosure.

7.Connect the red and white wires to the power supply. Attach the ground to the ground screw on the junction plate cover.

8.Replace the blower access cover.

9.Attach the black & white wires to the back of the thermal switch and install at the rear of the firebox using the thermal switch support bracket as circled in (FIGURE 9).

10.Replace the hearth pads.

 

BLOWER

BLACK

 

RED

 

WHITE

 

THERMAL DISC

 

 

VARIABLE

 

SPEED

FIGURE 11

SWITCH

WITHOUT THERMAL SWITCH BRACKET

1.Remove the hearth pads and blower access cover. (FIGURE 9)

2.Install the blower using the optional blower installation instructions.

3.Cut the red wire as close to the plug as possible.

4.Cut the black wire as close to the flag connection as possible. (FIGURE 12).

5.Using a box connector, connect supply wire though the junction cover plate located on the right side of the firebox enclosure.

6.Attach the ground to the ground screw on the junction plate cover.

7.Replace the blower access cover plate and hearth pads.

 

BLOWER

BLACK

 

RED

 

WHITE

 

THERMAL DISC

 

 

VARIABLE

 

SPEED

FIGURE 12

SWITCH

2 3

1

4

 

1.Hearth Pads

2.Blower Access Cover

3.Thermal Switch Support Bracket

4.7/8” Bushing

5.Junction Box

5

 

 

W

 

 

E

 

 

C

R

 

 

S

 

 

D

 

N

 

 

GROU

 

 

 

FIGURE 9

W415-0527/ 09.29.05

Page 9
Image 9
Napoleon Fireplaces ZCVF36, ZCVF42 With Thermal Switch Bracket, Blower, Thermal Disc, Variable, Speed