LEAK TESTING INSTRUCTIONS
DO NOT USE A FLAME TO LEAK TEST.
LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. No smoking while performing this test, and remove all sources of ignition. See Leak Testing Diagram for areas to check.
1.Turn all burners controls to off. Turn supply valve on.
2.Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.
3.Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.
4.If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer. Do not use the appliance until the leak has been corrected.
5.Turn off gas supply.
REGULATOR
The following tables lists input values for the appliance.
308 UNITS | BURNER | ORIFICE SIZE | HEAT INPUT | GAS USAGE (TOTAL) | ||
|
| I | II | (TOTAL) | PROPANE | BUTANE |
| MAIN | 60 | 64 | 8.8 kW | 629 g/h | 640 g/h |
| BACK | 60 | 64 | 4.4 kW | 315 g/h | 320 g/h |
| SIDE | 60 | 64 | 4.5 kW | 322 g/h | 327 g/h |
450 UNITS | BURNER | ORIFICE SIZE | HEAT INPUT | GAS USAGE (TOTAL) | ||
|
| I | II | (TOTAL) | PROPANE | BUTANE |
| MAIN | 63 | 65 | 12.3 kW | 879 g/h | 894 g/h |
| BACK | 58 | 60 | 5.6 kW | 400 g/h | 407 g/h |
| SIDE | 60 | 64 | 4.5 kW | 322 g/h | 327 g/h |
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category | I3B/P(30) | I3B/P(50) | |
Orifice Sizes (see above) | I | I | II |
Gases / Pressures | Butane 30mbar | Butane | Butane 50mbar |
| Propane 30mbar | Propane 37mbar | Propane 50mbar |
|
|
|
|
Countries | DK, FI, NL, NO, | BE, ES, FR, GB, | DE, AT |
| SE | IE, IT, PT |
|
|
|
|
|
The regulators for both butane and propane 308 units must have a rating of at least 1000 g/h. The regulators for both butane |
|
and propane 450 units must have a rating of at least 1200 g/h. Do not tamper with or modify regulator. Use only regulators | 5 |
which supply the pressure listed in the table above. |