Leak Tesng InstruconsWARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames are
in the area while you check for leaks. Sparks or open ames will result in a re or explosion, damage to
property, serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak Tesng
Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one recommended
by the Napoleon Customer Care department and have the grill inspected by a cered gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill inspected
by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. A exible metal connector is included to simplify the
installaon of the unit. Connect this connector to the are ng on the end of the manifold. Connect the
other end of the connector to the gas piping. Ensure that the connector does not pass through a wall, oor,
ceiling or paron, and is protected from damage. Do not use a hose to connect the unit. It must be con
nected
with rigid pipe, copper tube or an approved exible metal connector which complies with Z21.4 /CSA 6.10.
The installaon must comply with CAN B149.1 Natural Gas and Propane Installaon Code in Canada, or to the
Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner,
a separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon.
WARNING! Built in units are supplied with a drip pan which holds only a minimal amount of grease. To
prevent grease res, the pan must be cleaned aer each use.
WARNING! Access must be provided to the inside of the enclosure to make gas connecons.
DANGER! Read all instrucons carefully before operang the grill. Failure to follow these instrucons
exactly could result in a re causing serious injury or death. The enre installaon must be leak tested before
operang the grill.