the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner, a
separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon. If the enclosure is to house a propane cylinder, the tank poron of the enclosure must be venlated
according to local codes, and must not have communicaon with the cavity used to enclose the gas grill. A
propane cylinder can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
1. At least one unobstructed venlaon opening on the exposed exterior side of the enclosure located within
5 in (127 mm) of the top of the enclosure. The opening must have a total free area of more than 20 in2 (130
cm2 ) for a 20 lb (9.1 kg) cylinder and 30 in2 (195 cm2) for a 30 lb (13.6 kg) cylinder.
2. At least one venlaon opening on the exposed, exterior side of the enclosure located 1 in (25.4 mm) or
less from the oor level. The opening must have a total free area of more than 10 in2 (65 cm2) for a 20 lb
(9.1 kg) cylinder and 15 in2 (100 cm2) for a 30 lb (13.6 kg) cylinder. The upper edge must be no more than 5
in (127 mm) above the oor level.
Every opening must be large enough to permit the entrance of a 1/8 in (3.2 mm) rod.
WARNING!
The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to gain access
to the cylinder valves is acceptable, provided it is non-locking and can be opened without the use of tools.
The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to provide
shielding from radiaon, a ame barrier, and protecon from foreign material, such as hot drippings.
The enclosure cannot be located directly below the grill.
There must be a minimum clearance of 2 in (51 mm) between the oor of the LP-gas cylinder enclosure
and the ground.
The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected and the
connecons inspected and tested outside the cylinder enclosure. Any connecons that can be disturbed
when installing the cylinder in the enclosure must be accessible for tesng inside the enclosure.
CYLINDER SIZE OPENING A AREA OPENING B AREA
20 lb (9.1kg) 20in2 (130cm2) 10in2 (65cm2)
30 lb (13.6kg) 30in2 (195cm2) 15in2 (100cm2)
5” (127mm)
MAXIMUM
1” (25.4mm)
MAXIMUM
OPENING
A
OPENING
B2” (51mm)
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
34” (864mm)
RECOMMENDED
5” (127mm)
MAXIMUM