OPTIONS

11

OPTIONS

GVF103-KT - PATENTED CATALYTIC

DOOR INSTALLATION

NOTE: ORNAMENTAL INSETS CAN NOT BE USED IN CONJUNCTION

WITH THE CATALYTIC DOOR

This unique patented catalytic system was designed to provide unparalleled safety and peace of mind. The top of the door contains four catalytic tiles which are designed to filter out combustion gases and limit the carbon monox- ide output. It is likely that with the fireplace in operation, the catalytic tiles will actually scrub the carbon monoxide nor- mally found in the room and reduce it to a lower level. The tiles must not be altered or removed. They are not field serviceable and must be tested annually. The hood sup- plied with the unit must be disgarded and replaced with the hood designed for use with the catalytic door.

The heater with an optional catalytic door in place must not be operated when using any products such as paint, paint thinner, adhesives, etc. These products will perma- nently affect the catalytic tiles’ ability to scrub the air.

FIGURES 18

CURTAIN ROD BRACKET

1

1.The mesh must be removed if the catalytic door is used. Remove the centre bracket and bend the curtain rod slightly to disengage the rod from either side.

LATCH SCREW

LOCATION

CURTAIN SUPPORT PLATE

2

2.Remove the curtain support plate. Remove the two latch securing screws, already installed, position latch as shown in 4 and re-secure with the screws. A ¼” socket ratchet is recommended for this.

DOOR HINGE

3

3.Screw the door hinge onto the heater by first starting each of the five machine screws and then tightening all screws.

TOP DOOR LATCH

4

4.& 5. Secure the door using the two latches.

Install the appropriate hood by hooking it over the top lip of the door assembly.

The heater must not be used when the hood is removed.

BOTTOM DOOR LATCH

5

Care must be taken when closing and opening the cata- lytic door to avoid damaging the catalytic tiles.

CAUTION: The minimum clearance to a combusti- ble mantle is 12” when using a catalytic door.

Repeat at the bottom. For location, see