14
OPERATION / MAINTENANCE
If heater shuts off, do not relight until you provide fresh air. If heater keeps shutting off, have it serviced. Keep burner and control compartment clean.
When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary con- dition caused by the curing of the logs and the "burn- in" of internal paints and lubricants used in the manu- facturing process and will not occur again.
After extended periods of
FOR YOUR SAFETY READ BEFORE LIGHTING:
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.
B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.
C. Use only your hand to push in and turn the gas control knob. Never use tools. If the knob will not push in and turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may re- sult in a fire or explosion.
D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
When lighting and
1.STOP! Read the above safety information on this la- bel.
2.Set the thermostat to lowest setting.
3.Turn off all electric power to the fireplace.
4.Open the control door. Turn the gas knob clockwise to off.
5.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor, STOP! Follow "B" in the above safety information on this label. If you don't smell gas go to the next step.
6.Find pilot located in front of the back log.
7.Turn gas knob
WHAT TO DO IF YOU SMELL GAS:
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the fire de-
partment. | FIGURE 29 |
| ILOT |
FIGURE 28 |
|
| P |
| F | O | |
|
| N | |
|
| F | |
|
| O |
|
OXYGEN DEPLETION SENSOR | GAS KNOB |
8.Depress and hold gas knob while lighting the pilot with the push button igniter. Keep knob fully depressed for one minute, then release. If pilot does not continue to burn repeat steps 3 through 7.
9. With pilot lit, turn gas knob
10.If equipped with remote
11.Turn on all electric power to the fireplace.
GAS KNOB AT OFF
OL |
|
|
|
| N |
| O |
HI | O |
| F |
|
| P | FIGURE 30 |
|
| TOL I | |
TOLIP |
|
|
TO TURN OFF GAS
1.Turn off all electric power to the fireplace if service is to be performed.
2.Push in gas control knob slightly and turn clockwise to off. Do not force.