MID-7604/7602Power Drive 30 ni.com
EnvironmentOperatingtemperature ............................ 0 to 40 ºC (32 to 104 ºF)
Storagetemperature ................................–20 to 70 ºC(–4to158ºF)
Humidity.................................................10 to 90% RH, noncondensing
Maximum altitude...................................2000m
Pollutiondegree ......................................2
Usage......................................................Indoor use only
Electromagnetic CompatibilityEMC/EMI...............................................CE, C-Tick and FCC Part 15
(Class A) Compliant
Electricalemissions ................................EN 55011 Class A @ 10 meters
FCCPart 1 5A above 1 GHz
Electricalimmunity ................................Evaluated to EN 61326:1998,
Table 1
Note This deviceshould only be operated wi th shielded cabling for full EMC & EMI
compliance. Refer to the Declaration of Conformity (DoC) for this product for any
additionalregulatory compliance information. The DoC for this product is available via the
followingweb site: http://digital.ni.com/hardref.nsf. This site lists t he DoCs
byproduct family. Select the appropriate product family, followed by your product and a
link to the DoC will appear in Adobe Acrobat format. Click on the Acrobat icon to
downloador read the DoC.
SafetyMeetst he requirements of the following standardsf or safety for electrical
equipmentfor measurement, control, and laboratoryuse:
•EN 61010-1:1993/A2:1995, IEC 61010-1:1990/A2:1995
•UL 3101-1:1993, UL 3111-1:1994, UL 3121-1:1998
•CAN/CSA C22.2 No. 1010.1:1992/A2:1997
ULRecognized to UL 508C, power conversion equipment, File # E208822