Chapter2 Installation
©NationalInstruments Corporation 2-5 GPIB-SCSI-Afor Solaris
Configuration Switch Settings for SW2
TheDIP switch at location SW2 on the rear panel (see Figure 2-1) is used
to configure the mode of operation for the GPIB-SCSI-A. These switch
settings should not be changed for use with the Sun SPARC system.
Figure 2-3 shows the factory default settings. Make sure that these switches
are set as shown in Figure 2-3. If they are not, set these switches as
indicated.
Figure2-3. SW2 Default Mode Switch Settings
Table2-3 shows the factory default configurations of the eight switches
for SW2.
Table2-3. Factory Default Configurations for SW2
Switch Position Indication
1–3OFF Reservedand should remain OFF
4ON Double bufferingis enabled
5OFF GPIB-SCSI-Acompletes all data requests
to the count specified
6ON GPIB-SCSI-A buffersdata during data
transfercommands
7ON GPIB-SCSI-Aneither notices norreports
SCSIparity errors
8OFF Operatingi n S(SCSI) mode
SW212345678
9120
O
N
CTS 206-8
GS.book Page 5 Tuesday,June 12, 2001 2:17 PM