Chapter 3 Signal Connections
NI PCI-8254R User Manual 3-8 ni.com
CablingIEEE 1394 Camera Cables
You can connect cameras to the NI 8254R using standard IEEE 1394
cables. IEEE 1394 cables provide both a data path and power to your
camera.
40 27 ISO Input 8 Pulse generator
trigger input Trigger Change
Detector,
General-purpose
input
41 29 ISO Input 9 General-purpose
input Trigger Change
Detector,
General-purpose
input
42 32 Ciso Isolated
common-mode
signal
—
43 30 ISO Input 10 General-purpose
input Trigger Change
Detector,
General-purpose
input
44 31 ISO Input 11 User shutdown General-purpose
input
* TRIG 0, TRIG 1, and TRIG 2 are not available on the 37-pin terminal block or the signal accessory. If you need access to
these signals, you can get them directly from the 44-pin D-SUB connector.
Table 3-3. Signal Connections (Continued)
44-Pin D-SUB
on NI 8255R
Device Pin
Number 37-Pin Terminal
Block Number Signal Name Primary
Function Alternate