© National Instruments Corporation 9 NI TB-2709 Installation Guide
Physical
Dimensions
Height..............................................10.7 × 8.6 × 2.0 cm
(4.2 × 3.4 × 0.8 in.)
Weight.............................................144.6 g (5.1 oz)
I/O connectors
68-position SCSI-II type.................1, female
SMB jacks.......................................9
14-pin auxiliary connector..............One, Molex 14-pin microfit
connector
Shock and Vibration
Operational shock.................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating........................................ 5 to 500 Hz, 0.3 grms
Nonoperating.................................. 5 to 500 Hz, 2.4 grms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
Environment
The NI TB-2709 is intended for indoor use only.
Operating temperature............................0 to 55 °C
Storage temperature............................... –20 to 70 °C
Relative humidity...................................10 to 90% noncondensing
Pollution Degree.................................... 2