Care and Maintenance

2.Cut and discard the safety wire. (The wire prevents the packing gland nut from loosening.)

3.Hold the gland nut (large nut) with a pipe wrench and loosen the locking nut with another pipe wrench.

CORC108

4.HAND-TIGHTEN the gland nut until the dripping slows down to about 6-10 drips per minute.

CORC109

5.Using wrenches as in step 3, re-tighten the locking nut against the gland nut. Make sure it is VERY TIGHT. If you still experience leakage, consult your Correct Craft dealer.

6.Loosen one of the hose clamps at the rear of the assembly. Rotate the assembly until the safety wire eyelet is on top, and retighten the hose clamps.

8-7

Page 153
Image 153
Nautique 2008 70141 manual CORC108