Chapter 2: Site Preparation

2-7

Electrical Environment

VFD AC Power Requirements

120 VAC, 60 Hz (US, Canada, and others) via a wall mount power supply

90‐264 VAC, 50‐60 Hz via a Universal Input power supply

VFD DC Power Requirements

10 VDC to 14VDC (0.8 A max. at 12VDC)

LCD AC Power Requirements

No AC P/S available. The LCD receives power from the host via a powered RS‐232 connector.

LCD DC Power Requirements

10.6VDC to 13VDC (160mA max at 12VDC)

Operational Environment

System Configuration

The VFD communicates with the host via the parallel port or EIA‐232 serial port of the host. Both interfaces are active at the same time. The display does not need to know which cable it is connected to.

However, both interface cables cannot be connected to the unit at the same time.

The LCD communicates with the host via the serial port only.