The external control equipment changes the VOLUME gain data of the PlasmaSync 4205W.
Transmission Data |
|
|
|
DFH 80H 60H 7FH 03H DATA00 | DATA01 | DATA02 CKS | |
DATA00: USER SOUND Gain Flag | 05H |
|
|
DATA01: VOLUME Gain Flag | 01H |
|
|
DATA02: VOLUME Gain |
|
|
|
| 00H: Step 0 |
|
0AH: Step 10 (Default)
2AH: Step 43
ACK |
|
|
|
7FH 60H 80H 7FH 02H DATA00 | DATA01 | CKS | |
DATA00: USER SOUND Gain Flag | 05H |
|
|
DATA01: VOLUME Gain Flag | 01H |
|
|
The external control equipment switches the screen mode of the PlasmaSync 4205W.
Transmission Data |
|
|
|
|
| |
DFH 80H | 60H | 51H | 01H | 01H DATA00 | CKS | |
DATA00 | 02H : STADIUM |
|
|
| ||
| 03H | : ZOOM |
|
|
| |
| 04H | : NORMAL |
|
|
| |
| 05H | : FULL |
|
|
|
|
ACK |
|
|
|
|
|
|
7FH 60H | 80H | 51H | 01H | DATA00 | CKS |
|
DATA00 | 02H : STADIUM |
|
|
| ||
| 03H | : ZOOM |
|
|
| |
| 04H | : NORMAL |
|
|
| |
| 05H | : FULL |
|
|
|
|
The external control equipment switches on AUDIO Mute of the PlasmaSync 4205W.
Transmission Data
9FH 80H 60H 3EH 00H CKS
ACK
3FH 60H 80H 3EH 00H CKS
07.AUDIO Mute Off FunctionThe external control equipment switches off AUDIO Mute of the PlasmaSync 4205W.
Transmission Data
9FH 80H 60H 3FH 00H CKS
ACK
3FH 60H 80H 3FH 00H CKS
42