Function
The external control equipment changes the RED Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag | 01H |
| |
DATA01: RED Gain Flag | 01H |
| |
DATA02: RED Gain 1 (Bias) | D8H: | ||
|
| ||
|
|
| |
| FFH: | ||
| 00H: | 0 | |
|
| ||
|
|
| |
| 28H: +40 | ||
DATA03:RED Gain 2 (Drive) | D8H: | ||
|
| ||
|
|
| |
| FFH: | ||
| 00H: | 0 | |
|
| ||
|
|
| |
| 28H: +40 | ||
ACK |
|
|
|
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: USER PICTURE Gain Flag | 01H |
| |
DATA01: RED Gain Flag | 01H |
|
Function
The external control equipment changes the GREEN Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag | 01H |
| |
DATA01: GREEN Gain Flag | 02H |
| |
DATA02: GREEN Gain 1 (Bias) | D8H: | ||
|
|
| |
| FFH: | ||
| 00H: | 0 | |
|
|
| |
| 28H: +40 | ||
DATA03: GREEN Gain2 (Drive) | D8H: | ||
|
|
| |
|
|
| |
| FFH: | ||
| 00H: | 0 | |
|
|
| |
| 28H: +40 | ||
ACK |
|
|
|
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: USER PICTURE Gain Flag | 01H |
| |
DATA01: GREEN Gain Flag | 02H |
|
Function
The external control equipment changes the BLUE Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag | 01H |
| |
DATA01: BLUE Gain Flag | 03H |
| |
DATA02: BLUE Gain1(Bias) | |||
|
|
| |
|
|
| |
| |||
| 00H: | 0 | |
|
|
| |
| 28H: +40 | ||
DATA03: BLUE Gain2(Drive) | D8H: | ||
|
|
| |
| |||
| 00H: | 0 | |
|
|
| |
| 28H:+40 | ||
ACK |
|
|
|
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: USER PICTURE Gain Flag | 01H |
| |
DATA01: BLUE Gain Flag | 03H |
|
41