17.RED Gain Data

Function

The external control equipment changes the RED Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

DATA00: USER PICTURE Gain Flag

01H

 

DATA01: RED Gain Flag

01H

 

DATA02: RED Gain 1 (Bias)

D8H: -40

 

 

 

 

 

 

FFH: -1

 

00H:

0

 

 

 

 

 

 

28H: +40

DATA03:RED Gain 2 (Drive)

D8H: -40

 

 

 

 

 

 

FFH: -1

 

00H:

0

 

 

 

 

 

 

28H: +40

ACK

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

 

DATA01: RED Gain Flag

01H

 

18.GREEN Gain Data

Function

The external control equipment changes the GREEN Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

DATA00: USER PICTURE Gain Flag

01H

 

DATA01: GREEN Gain Flag

02H

 

DATA02: GREEN Gain 1 (Bias)

D8H: -40

 

 

 

 

FFH: -1

 

00H:

0

 

 

 

 

28H: +40

DATA03: GREEN Gain2 (Drive)

D8H: -40

 

 

 

 

 

 

 

FFH: -1

 

00H:

0

 

 

 

 

28H: +40

ACK

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

 

DATA01: GREEN Gain Flag

02H

 

19.BLUE Gain Data

Function

The external control equipment changes the BLUE Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

DATA00: USER PICTURE Gain Flag

01H

 

DATA01: BLUE Gain Flag

03H

 

DATA02: BLUE Gain1(Bias)

D8H:-40

 

 

 

 

 

 

 

FFH:-1

 

00H:

0

 

 

 

 

28H: +40

DATA03: BLUE Gain2(Drive)

D8H: -40

 

 

 

 

FFH:-1

 

00H:

0

 

 

 

 

28H:+40

ACK

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

 

DATA01: BLUE Gain Flag

03H

 

41