RS-232C - continued
The following control sequence is used for a single monitor
When using the following control commands, all of the
1) Interface
PROTOCOL | |
|
|
BAUD RATE | 9600 [bps] |
|
|
DATA LENGTH | 8 [bits] |
|
|
PARITY BIT | NONE |
|
|
STOP BIT | 1 [bit] |
|
|
FLOW CONTROL | NONE |
|
|
2) Control command diagram
The command is structured by the address code, function code, data code and end code. The length of the command is different for each function.
| Address Code | Function Code | Data Code |
| End Code | ||
|
|
|
|
|
|
|
|
HEX |
| 30h | 30h | Function | Data |
| 0Dh |
|
|
|
|
|
|
|
|
ASCII |
| '0' | '0' | Function | Data |
|
|
|
|
|
|
|
|
| |
[Address code] | 30h 30h (In ASCII code, '0' '0') fixed. |
| |||||
[Function code] | A code of each fixed control move. |
| |||||
[Data code] |
| A code of each fixed control data (number) and |
| ||||
|
|
| not always indicated. |
|
|
| |
[End code] |
| 0Dh (In ASCII code, ' ' ) fixed. |
|
To control multiple monitors that are daisy- chained together please use the extended control command.