NEC 50XC10, 60XC10, 42XC10 user manual RS-232C - continued, Interface, Control command diagram

Models: 42XC10 60XC10 50XC10

1 41
Download 41 pages 6.17 Kb
Page 27
Image 27
RS-232C- continued

RS-232C- continued

The following control sequence is used for a single monitor

When using the following control commands, all of the daisy-chained monitors can be controlled at the same time from the primary monitor. However, reply and status commands will only pertain to the primary monitor, and not to the secondary monitors.

1) Interface

PROTOCOL

RS-232C

 

 

BAUD RATE

9600 [bps]

 

 

DATA LENGTH

8 [bits]

 

 

PARITY BIT

NONE

 

 

STOP BIT

1 [bit]

 

 

FLOW CONTROL

NONE

 

 

2) Control command diagram

The command is structured by the address code, function code, data code and end code. The length of the command is different for each function.

 

Address Code

Function Code

Data Code

 

End Code

 

 

 

 

 

 

 

 

HEX

 

30h

30h

Function

Data

 

0Dh

 

 

 

 

 

 

 

 

ASCII

 

'0'

'0'

Function

Data

 

 

 

 

 

 

 

 

 

[Address code]

30h 30h (In ASCII code, '0' '0') fixed.

 

[Function code]

A code of each fixed control move.

 

[Data code]

 

A code of each fixed control data (number) and

 

 

 

 

not always indicated.

 

 

 

[End code]

 

0Dh (In ASCII code, ' ' ) fixed.

 

To control multiple monitors that are daisy- chained together please use the extended control command.

English-24

Page 27
Image 27
NEC 50XC10, 60XC10, 42XC10 user manual RS-232C - continued, Interface, Control command diagram