Default Features

Default Features for Lines

1.All lines are loop start DTMF.

Use 3101-01: Line Type to change this assignment.

2.• Lines 1-12 ring on line keys 1-12 for extensions 300-315. (Lines 13-64 do not appear on line keys.)

All other extensions are lamp only for lines 1-12.

To customize line ringing, use one of the following:

3.• User Programmable Features code #RAL. (See the User Programmable Features feature for more.)

• Use 2132-[01-64]: Line Ringing.

Default Features for Extensions

1.The circuit types for keyset extensions are automatically set when the extension is plugged in. Keyset users can place outside calls by:

2.• Pressing a line key and dialing the outside number. (See the Central Office Calls, Placing feature for more.)

Pressing INTERCOM, dialing 9, then dialing the outside number. (See the Line Group Routing feature for more.)

Line Dial-Up and Direct Line Access are disabled. (See the Central Office Calls, Placing feature for more.)

3.All extensions have full incoming and outgoing access to all outside lines.

See Initial Startup Programming below to change this assignment.

4.By default, Feature Keys 1-12 are line keys. Keys 13-24 are undefined. See the Feature Keys feature for more.

Default Features for IntraMail

1.Each extension has an IntraMail voice mailbox.

2.All mailboxes are enabled. To disable a mailbox, see 2141-01: Station Mailbox Type.

3.The IntraMail Automated Attendant does not answer outside calls. (See the Automated Attendant feature for more.)

Initial Startup Programming

1.Enter the programming mode.

1.From any display telephone, press INTERCOM + Dial #*#* + Enter the system password + HOLD.

2.The system passwords are:

-632379 (NECDSX) for Installer (level 3), 9999 for System Administrator 2 (level 2), 0000 for System Administrator 1 (level 1).

2.Assign the correct circuit type to each of your installed lines.

1.In 3101-01: Line Type, assign the correct circuit type for each line. Analog line types are:

-51 for loop start DTMF, 52 for loop start DP.

3.By default, each extension has full incoming and outgoing access to each line. To change this assignment:

1.In 2131-[01-64]: Line Access, change each extension’s line access as required. The options are:

-0 for no access, 1 for incoming access only, 2 for outgoing access only, 3 for full access

2.Using 902x-Copymay save you time.

4.By default, extensions 300-315 ring immediately day and night for lines 1-12. To change this assignment:

1.In 2132-[01-64]: Line Ringing, set the ringing option for each extension, The options are:

-0 for lamp only (no ringing) day and night, 1 for day and night ringing, 2 for night ringing only, 3 for delay ringing day and night

2.Using 902x-Copymay save you time.

5.To change the default system passwords:

1.Turn to the System Programming Password Protection feature to learn more about system passwords.

(1093088)

June 15, 2006, Rev 1

Empowered by Innovation

Printed in U.S.A.

 

Page 2
Image 2
NEC DSX-160 quick start Default Features, Initial Startup Programming