7. Appendix
PC Control Codes and Cable Connection
PC Control Codes
Function | Code Data |
|
|
|
|
|
| |
POWER ON | 02H | 00H | 00H | 00H | 00H | 02H |
|
|
POWER OFF | 02H | 01H | 00H | 00H | 00H | 03H |
|
|
INPUT SELECT COMPUTER | 02H | 03H | 00H | 00H | 02H | 01H | 01H | 09H |
INPUT SELECT COMPUTER 1 (NP216 only) | 02H | 03H | 00H | 00H | 02H | 01H | 01H | 09H |
INPUT SELECT COMPUTER 2 (NP216 only) | 02H | 03H | 00H | 00H | 02H | 01H | 02H | 0AH |
INPUT SELECT VIDEO | 02H | 03H | 00H | 00H | 02H | 01H | 06H | 0EH |
INPUT SELECT | 02H | 03H | 00H | 00H | 02H | 01H | 0BH | 13H |
PICTURE MUTE ON | 02H | 10H | 00H | 00H | 00H | 12H |
|
|
PICTURE MUTE OFF | 02H | 11H | 00H | 00H | 00H | 13H |
|
|
SOUND MUTE ON | 02H | 12H | 00H | 00H | 00H | 14H |
|
|
SOUND MUTE OFF | 02H | 13H | 00H | 00H | 00H | 15H |
|
|
NOTE: Contact your local dealer for a full list of the PC Control Codes if needed.
Cable Connection
Communication Protocol |
|
|
Baud rate ���������������������������������� | 對������ | 38400 bps |
Data length ���������������������������������� | 對��� | 8 bits |
Parity ���������������������������������� | 對������������ | No parity |
Stop bit���������������������������������� | 對��������� | One bit |
X on/off���������������������������������� | 對��������� | None |
Communications procedure............. | Full duplex |
NOTE: Depending on the equipment, a lower baud rate may be recommended for long cable runs.
PC Control Connector
To TxD of PC
To RxD of PC
To GND of PC
1 2 3 4 5
6 7 8 9
To RTS of PC
To CTS of PC
NOTE 1: Pins 1, 4, 6 and 9 are no used.
NOTE 2: Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection.
NOTE 3: For long cable runs it is recommended to set communication speed within projector menus to 9600 bps.