Installation to Concrete Ceilings

Illustration AWARNING

When installing Peerless mounts on concrete, verify that you have a minimum of 1 5/8" of actual concrete surface in the 1/4" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Concrete must meet ASTM C-90 specifications.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard- ware and components.

Never exceed the Maximum UL Load Capacity of 50 lb (27 kg).

Installation to Concrete Ceilings

ACC 203 (Alligator® concrete anchors) are recommended.

Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (G) using two concrete anchors and #14 x 2.5" wood screws (F) as shown in Illustration A and 1, 2, and 3 (below). Tighten all fasteners.

IMPORTANT: It is the responsibility of the installer to verify that the ceiling will safely support the combined load of all attached hardware and components.

concrete anchor

CONCRETECEILING

Manual backgroundWARNING

Tighten wood screws so that ceiling plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.

Never tighten in excess of 80 in • lb (9 N.M.).

Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is highly recommended.

G Manual backgroundManual backgroundManual background

F Manual backgroundManual background

Illustration A

1

 

concrete

 

 

WARNING

 

 

ceiling

FOR DIRECT ATTACHMENT TO LOAD BEARING

 

 

concrete

 

 

 

CONCRETE ONLY! Concrete expansion anchors are

 

 

anchor

 

not intended for attachment to concrete ceilings

 

 

 

 

 

 

Drill hole and insert anchor

G

 

 

covered with a layer of plaster, drywall, or other

 

2

 

 

finishing material. If mounting to concrete ceiling

 

 

covered with plaster / drywall is unavoidable, plaster /

 

F

concrete

 

drywall must be counterbored as shown below.

 

 

 

 

 

 

 

 

anchor

 

 

INCORRECT

CORRECT

 

 

 

 

Place ceiling plate over anchor and secure with screw

VIEW

 

 

 

 

3

 

 

metal

concrete

metal

concrete

 

 

CUTAWAY

bracket

bracket

After repeating step one tighten all fasteners

dry wall

dry wall

 

 

F

concrete

 

 

 

 

 

 

anchor

 

plaster/

plaster/

 

 

 

 

4 of 8

 

ISSUED: 11-01-06 SHEET #: 055-9478-6 01-14-09