Operation instructions
SLEEPmode
SLEEP mode
SLEEP mode can be set in COOLING or HEATING operation mode. This function gives you a more comfortable environment for sleeping.
In SLEEP mode,
The appliance will stop operation automatically after operating for 8 hours.
Fan speed is automatically set at low speed.
*Set temperature will rise by 1℃ at most if the appliance operates in cooling mode for 2 hours constantly, then keeps steady.
Set temperature will decrease by 3℃ at most if the appliance operates in heating mode for 3 hours constantly, then keeps steady.
*Note: In cooling mode, if room temperature is 26℃or above, set temperature will not change.
Note: Heating is NOT available for cooling only air conditioner.
SU PE R | SMART |
SLEEP
SUPERmode
SUPER mode
SUPER mode is used to start or stop fast cooling.
Fast cooling operates at high fan speed, changing the set temperature automatically to 18℃.
SUPER mode can be set when the appliance is in operation or energized.
In SUPER mode, you can set airflow direction or timer. If you want to escape from SUPER mode, press any
mode.1
Note:
SLEEP and SMART buttons are not available in SUPER mode.
SUPER button is ineffective in HEATING mode.
The Appliance will continue working in SUPER mode with set temperature of 18℃, if you. don't escape from it by pressing any of the buttons mentioned above.
PERSMART
SLEEP
11
PDF created with pdfFactory Pro trial version www.pdffactory.com