ALCOVE INSTALLATION REQUIREMENTS

ALCOVE INSTALLATION REQUIREMENTS

The American Harvest is approved for the standard alcove height of 72 inches, or for a reduced alcove height with a minimum of 14 inches from the top of the stove (clearance for opening top lids). The maximum alcove depth is 60 inches and the listed clearances are a minimum of 1 inch. The 14” clearance is only needed for opening the back lid. If the front lid protrudes out of the opening a 1” clearance is all that is required.

ALCOVE CLEARANCE RECOMMENDATIONS

47” Min.

1” Min.

Sides &

Rear

ALCOVE-THROUGH THE WALL INSTALLATION REQUIREMENTS

The stove is approved for horizontal exhaust, however, we recommend that the exhaust goes vertically for five feet, or above the eaves of the house. This will help draw smoke out of the stove in the event of a power failure.

1” min.

Corner Installation

 

Wall Thimble

Termination Cap

 

Type “PL” Vent

2 ft. Horizontal Pipe

6” min.

12” min.

ALCOVE CLEARANCE RECOMMENDATIONS Non Combustible

Hearth Pad

Outside Wall Termination

Wall Thimble

Optional Air

 

Intake

Termination

Cap

Optional

Direction