PROBLEM

 

CAUSES

 

SOLUTIONS

 

 

 

 

 

? Fire goes out or stove shuts down

Hopper is empty.

Refill hopper.

automatically.

• Fuel is not feeding.

 

See “Pellets will not feed” below

 

 

 

High limit temperature switch has

Allow stove to cool for 1 hour and

 

 

tripped.

 

relight. If the stove has been oper-

 

 

 

 

ating at a medium to high burn and

 

 

 

 

the convection fan has been turned

 

 

 

 

down low, then the fan should be

 

 

 

 

turned up higher. If this problem

 

 

 

 

persists, particularly at lower burn

 

 

 

 

rates, then the high limit snap switch

 

 

 

 

should be replaced by your local

 

 

 

 

dealer.

 

• Combustion air too high.

Adjust the damper to reduce com-

 

 

 

 

bustion airflow.

 

Fuel feed rate is too low.

• Have an USSC reseller qualified

 

 

 

 

technician adjust the fuel control.

 

 

 

 

 

? Pellets will not feed.

Hopper is empty.

Check contents of the hopper. Add

 

• Auger, circuit board, pressure switch

 

fuel if necessary.

 

 

 

 

 

or relay

Have your USSC reseller diagnose

 

 

 

 

the problem and replace the part(s).

 

 

 

 

 

? Stove runs for 30 minutes and then

Exhaust gas is not up to tempera-

Relight the stove

shuts down.

 

ture.

 

 

 

• Low limit snap switch not operating

• Have your USSC reseller replace the

 

 

properly; may be defective.

 

low limit switch.

 

Wires to the low limit snap switch

Contact your USSC reseller for ser-

 

 

(mounted on the side of the firebox)

 

vice.

 

 

are either loose or disconnected.

 

 

 

 

 

 

? Blower will not shut off after the fuel

Low limit snap switch has failed in

• Have your USSC reseller replace the

has been switched off and the stove

 

the closed position.

 

low limit switch.

has cooled down.

 

 

• It can take up to 1 hour for the unit

 

 

 

 

 

 

 

to cool down enough for the blower

 

 

 

 

to shut off. If it takes longer than 2

 

 

 

 

hours for the blower to shut off or if

 

 

 

 

it fails to shut off completely contact

 

 

 

 

your local USSC service technician.

 

 

 

 

 