Troubleshooting
Checking the machine on receipt
The receipt check enables you to rapidly locate faults on the machine and to initiate appropriate repair action.
Follow the check procedure.
Repair any faults found and check if the machine is operating perfectly.
Check procedure | Symptoms | Action / repair work | Further action / repair work |
|
|
|
|
| 1.1 Parts of housing broken or damaged | YES - Replace parts if necessary |
|
1 Check appliance for visible | NO - Go to point 1.2 |
| |
|
| ||
damage | 1.2 Mains cable damaged | YES - Replace mains cable |
|
| NO - Plug machine to the mains and go to point 2.1 |
| |
|
|
| |
|
|
|
|
|
| YES - Go to point 2.2 |
|
|
|
|
|
| 2.1 Closing handle works correctly |
| YES - Screw on new closing handle screws at |
| NO - It is hard or impossible to close the closing handle | defined torque (see page 22) or replace CBU | |
|
| ||
2 Check mechanical elements |
|
| NO - Replace the CBU |
|
|
| |
2.2 Is the capsule correctly ejected? | YES - Go to point 2.3 |
| |
|
| ||
| NO - Replace CBU |
| |
|
|
| |
|
|
|
|
| 2.3 Is the capsule cage seal damaged? | YES - Replace CBU |
|
| (feel with a finger if the seal is damaged) | NO - Go to point 3 |
|
|
|
|
|
3 Fill water tank | 3.1 Water tank is leaking | YES - Replace water tank |
|
NO - Go to point 4 |
| ||
|
|
| |
|
|
|
|
|
| YES - a) Check if mains cable is functional | YES - Go to point b) |
|
| NO - Replace it | |
|
|
| |
|
|
|
|
|
| YES - b) Check if On/Off switch is functional | YES - Go to point c) |
|
| NO - Replace it | |
|
|
| |
|
|
|
|
|
| YES - c) Check if pump is working (press coffee | YES - Go to point f) |
4 |
| button) | NO - Go to point d) |
4.1 Machine is not working (no function) |
|
| |
YES - d) Check if coffee buttons are functional | YES - Go to point e) | ||
automatic self test |
| NO - Replace defective button(s) | |
|
|
| |
|
|
|
|
|
| YES - e) Check if pump's fine wire fuse (128°C) is | YES - Replace it |
|
| defective | NO - Replace pump |
|
|
|
|
|
| YES - f) Check if thermoblock’s fine wire fuse (167°C) | YES - Replace it together with electronic control |
|
| is defective | board and if necessary with the thermoblock |
|
| NO - Go to point g) | |
|
|
| |
|
|
|
|
Service Manual EF 473 / EF 474 | 15 | Version 1.0 en |