AGM732F

Absolute Maximum Ratings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

 

Note

 

Storage Temperature

Ts

-40

 

85

ºC

 

 

 

Supply Voltage

VCC

0

 

5

V

 

 

 

Recommended Operating Conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

 

Note

 

Case Operating Temperature

TC

-5

 

70

ºC

 

 

 

Supply Voltage

VCC

3.135

 

3.465

V

 

 

 

Electrical Characteristics

 

 

 

 

 

 

 

 

(VCC=3.135V to 3.465V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

 

Note

 

Total Supply Current

ICCT

 

180

300

mA

 

 

 

Transmitter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmitter Differential Input Voltage

VDT

0.5

 

2.4

V

 

1

 

Transmitter Disable Input-High

VDISH

2

 

VCC+0.3

V

 

 

 

Transmitter Disable Input-Low

VDISL

0

 

0.8

V

 

 

 

Transmitter Fault Output-High

VTXFH

2

 

VCC+0.3

V

 

2

 

Transmitter Fault Output-Low

VTXFL

0

 

0.8

V

 

2

 

Receiver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receiver Differential Output Voltage

VDR

0.35

0.7

2

V

 

3

 

LOS Output Voltage-High

VLOSH

2

 

VCC+0.3

V

 

2

 

LOS Output Voltage-Low

VLOSL

0

 

0.8

V

 

2

 

Output Data Rise/Fall Time

tr / tf

 

 

400

psec

 

4

 

Total Jitter (pk-pk)

TJRX

 

 

220

psec

 

 

 

Notes:

1.Internally AC coupled and terminated to 100Ohm differential load.

2.Pull up to VCC with a 4.7K – 10K Ohm resistor on host Board

3.Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/ Deserializer.

4.These are 20%~80% values