Troubleshooting
If the
1.Is the PWR (power) LED illuminated?
NO
•Ensure that the power adapter is the proper type of voltage and cycle frequency for the outlet (See “Power Supply” on page 5.)
•Ensure the power adapter is properly installed in the converter and in the grounded outlet.
•Contact Technical Support: US/Canada:
International:
YES
•Proceed to step 2.
2.Are both LK1 & LK2 LEDs (fiber link for ports 1 & 2) illuminated?
NO
•Ensure both SFP transceiver modules are properly inserted in the converter.
•Check the fiber cables for proper connection.
•Verify that the TX and RX cables on the media converter are connected to the RX and TX ports, respectively, on the other device.
•Contact Technical Support: US/Canada:
International:
YES
•Proceed to step 3.
3.Is the LK1 LED (fiber link 1) flashing?
NO
•If there is no network activity on port 1, proceed to step 4.
•If there is network activity on port 1, disconnect and reconnect the fiber cables to restart the initialization process.
•Contact Technical Support: US/Canada:
International:
YES
•Proceed to step 4.
4Is the LK2 LED (fiber link 2) flashing?
NO
•If there is no network activity on port 2, contact technical support.
•If there is network activity on port 2, disconnect and reconnect the fiber cables to restart the initialization process.
•Contact Technical Support: US/Canada:
International:
Contact Us
Technical support
Technical support is available 24 hours a day.
US and Canada:
International:
Transition now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-based seminars
Transition Networks provides seminars via live
E-Mail
Ask a question anytime by sending an
Address Transition Networks
6475 City West Parkway Minneapolis, MN 55344, U.S.A.
telephone:
toll free:800-526-9267
fax:952-941-2322
| Declaration of Conformity |
Name of Mfg: | Transition Networks |
| 6475 City West Parkway, Minneapolis MN 55344 U.S.A. |
Model: | |
Part Number: | |
Regulation: | EMC Directive 89/336/EEC |
Purpose: To declare that the
EN 55022:1998 Class A; EN 55024: 1998+A1+A13164:2002; FCC Part 15 subpart B; 21CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
| June 6, 2006_____ |
Stephen Anderson, | Date |
6 | techsupport@transition.com | 7 |