RACKMOUNTING INSTRUCTIONS

NTI UNIMUX SERIES USB KVM SWITCH

RACKMOUNTING INSTRUCTIONS

This NTI switch was designed to be mounted to a rack or to sit on a desktop. It includes rackmount ears to make attachment to a rack easy, and rubber feet to be applied to the bottom of the case if it will instead sit on a flat surface. If this will sit on a flat surface, simply apply the rubber feet to the bottom of the case in each of the 4 corners.

To Mount in a Rack

1.Attach the ears to the switch using the 6-32x3/16" flat Phillips-head screws (6) provided as shown in the illustration below. The holes in the ears should line up with pre-threaded holes in the sides of the NTI switch. Tighten the screws securely.

NTI Switch

Front of Switch

To Mount in a RackFigure 1- Secure rackmount ears to switchRackFigure 2- Secure switch to a rackManual backgroundManual background 6-32x3/16"

Manual backgroundManual backgroundManual background Flat Head

Screws (Provided)

Rackmount Ear

Figure 1- Secure rackmount ears to switch

2.Install 4 cage nuts (not supplied) to the rack in locations that line up with the holes in the mounting ear on the NTI switch.

3.Secure the NTI switch to the rack using four rack screws (10-32, 12-24, M6, etc.- not supplied). Each screw should be of sufficient length to go completely through the NTI mounting ear, rack frame and fully engage all threads in the cage nut. Be sure to tighten all mounting screws securely.

4.Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.

NTI Switch

Rack

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Cage Nuts

(not supplied)

Rack Screws Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background (not supplied) Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Figure 2- Secure switch to a rack

5

Page 8
Image 8
Network Technologies UNIMUX-DVI-xHD Rackmounting Instructions, To Mount in a Rack, Secure rackmount ears to switch