recommended to use Alkaline batteries, which ensure the most stable performance.
b. Testing of operation in a daytime
During the bright time of the day:
Turn on the on/off switch (9). The lens cap (6) must be on. Direct the device at an object placed within
NOTE: The device won’t burn out even if it is exposed to a bright light. The automatic
CAUTION!
The device is not supposed to be directed at a bright source of light: bright lamps, the sun, welding and etc – it may result in the reduction of the light gain of the device. In order to avoid the fatigue of
c. Operation at night
AT MOON LIGHT: Take off the lens cover (6). Turn on the
AT INSUFFICIENT AMBIENT ILLUMINATION: use the Infra/Red illuminator activated by rotating switch (9). Select one of three positions of the switch for different IR power settings (10, 25 or 75 mW). If brightness of the screen is decreasing, replace the batteries.
It’s recommended to take out the batteries during long periods of
Do not forget to switch the device off after end of work!
8
(for example, .375 H&H Mag) your eye should be situated at the distance of
•Place inserts (4, 5) in the apertures of the rail (2). The insert (4) is placed with a pimple looking downwards in the nearest front slot of the rifle rail. If there is no such a slot, it’s recommended to make it at a gunsmith workshop.. It is recommended to place the inserts at the maximum possible distance from each other;
•Place clamps (6) and clamp screws (7) in the inserts (4, 5). Tighten screws (7) in order to obtain hard fixation. When necessary the excessive front part of the rail (3) can be removed.
Installation is completed and the device is ready for use as a hunting scope.
c. Variant III – side rail for East European (Warsaw Pact) rifles.
Side rail can be used for the installation of DN482/483 on a hunting rifle with side rail. The appearance of the device with a side rail is shown below:
It is recommended to contact NEWCON OPTIK for installation of the side rail.
ATTENTION! In case if you use other type of binding, to eliminate the phenomenon of shooting point displacement, device binding should be advised with Newcon Optik, because usually such displacement is caused by unqualified installation.
13