INSTALL THE BRUSHES
CAUTION !
Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.
1Make sure the Vacuum Deck is in the RAISED position. Make sure the Key Switch (A) is off (O).
2See Figure 2. Loosen both Thumb Screws (AA) slide the Idler Assembly (AB) down and off of the vacuum deck and away from the brush.
4Slide the brush into the housing, lift slightly, push and turn until it seats.