English
Trouble Shooting
Symptom | Possible cause | Action |
No power | Not connected / Faulty socket | Check connection to wall socket and |
|
| socket switch. Try in another wall socket |
| On / Off switch not on | Press On / Off switch which will illuminate |
|
| when on |
| Fuse blown | Replace fuse with approved 13A fuse |
| Unknown | Call for service |
No steam | Steam Control turned down fully | Turn the control to half way |
| clockwise |
|
| Steamer not ready | Wait for the “Ready to steam” light to |
|
| illuminate |
| Clean water tank is low (beeping | Pour water into the clean water tank until |
| sound& "refill" light is lit) | the beeper stops. The steam handle will |
|
| work again. |
| Unknown | Call for service |
No steam, Just water | Steamer not ready | Wait for the "Ready to steam " light to |
|
| illuminate |
| Boiler at pressure and not | Hold the steam switch on for |
| heating(temperature less than 110ºC) | approximately one minute, ever if just |
|
| water is coming out. This will result in the |
|
| heater coming back on |
| Unknown | Call for service |
Steam Leaking from front | “O” Rings split | Change and re grease “O” Rings. To |
socket |
| avoid this happening ensure “o” rings are |
|
| grease before every use. |
| “O” rings worn | Change and re grease “O” Rings. To |
|
| avoid this happening ensure “o” rings are |
|
| grease before every use. |
No detergent | Solution tank empty | Pour cleaning solution diluted in |
|
| accordance with the manufacturers |
|
| instructions into the solution tank. |
| Unknown | Call for service |
14