Poseidon 2
10 Main Technical Data
Type |
| Poseidon | Poseidon | Poseidon | Poseidon | Poseidon | Poseidon |
|
| ||||||
|
|
|
|
|
|
|
|
Rated pressure | bar/MPa | 100 | 69/6.9 | 120/12 | 140/14 | 150/15 | 150/15 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Permissible pressure | bar/MPa | 74/7.4 | 76/7.6 | 130/13 | 150/15 | 160/16 | 160/16 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Water flow, low pressure | l/min | 9 | 2.4 | 8.7 | 10.2 | 10 | 10 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Water flow, high pressure | l/min. | 8.7 | 2.1 | 7.8 | 9 | 9.5 | 9.5 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Rated input | kW | 1.3 | 1.7 | 2.3 | 2.9 | 3.3 | 3.3 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Rated voltage | V | 120 | 120 | 230 | 230 | 230 | 230 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Max. water temperature | °C | 60 | 60 | 60 | 60 | 60 | 60 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Inlet pressure | bar/MPa | 10/1.0 | 10/1.0 | 10/1.0 | 10/1.0 | 10/1.0 | 10/1.0 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Sound pressure level | dB(A) | 89.1 | 77,4 | 76.1 | 77.4 | 73.5 | 79.7 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Guaranteed sound power level | dB(A) | 91 | 92 | 91 | 92 | 88 | 94 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Vibration according to | m/s2 | < 2.5 | < 2.5 | < 2.5 | < 2.5 | < 2.5 | < 2.5 |
ISO | |||||||
Weight | kg | 27.1 | 28.1 | 28.1 | 27.1 | 26.3 | 28.1 |
|
|
|
|
|
|
|
|
11 EU Declaration of Conformity
EU Declaration of Conformity |
| |
Product: | High Pressure Washer |
|
Type: |
| |
| ||
| ||
Description: | 120 V, 230 V, 1~, 50 Hz - IP X5 | |
The design of the unit corresponds to the | EC Machine Directive | 2006/42/EC |
following pertinent regulations: | EC | 2006/95/EC |
| EC EMV Directive | 2004/108/EC |
Applied harmonised standards: | EN ISO | |
| EN |
|
| EN | |
Applied national standards and technical | BS EN |
|
specifications: |
|
|
|
| |
| Division of Nilfi | |
| Industrivej 1 |
|
Anton Sørensen |
| |
|
| |
General Manager, Technical Operations EAPC | Hadsund, 01.10.2010 |
|
|
|
|
Original Instructions | 75 |