MAINTENANCE AND REPAIR INSTRUCTIONS

SERVICING DOUBLE INSULATED UNITS

This unit is double-insulated. In a double-insulated unit, two systems of insulation are provided instead of grounding. There is no grounding provided and no means of grounding should be added to this unit.

Extreme care and knowledge of the system is required when servicing a double-insulated unit. Service should be performed by qualified service personnel only.

Replacement parts for a double-insulated unit must be identical to the parts they replace. Refer any repair to an authorized service dealer. A double-insulated unit is marked with the words “double insulation” or “double insulated.”

LINE INSTALLATION

This section covers both SplitLine™ and standard single line installation.

Always use original equipment manufacturer 0.065 in. (1.65 mm) replacement line. Line other than the specified may make the motor overheat or fail.

WARNING: Never use metal- reinforced line, wire,

chain or rope. These can break off and become dangerous projectiles.

There are two methods to replace the trimming line:

Wind the inner reel with new line

Install a prewound inner reel

Winding the Existing Inner Reel

1.Hold the outer spool with one hand and unscrew the Bump Knob™ counterclockwise (Fig. 11). Inspect the bolt inside the Bump Knob to make sure it moves freely. Replace the Bump Knob if damaged.

Bolt

Bump Knob™

Fig. 11

2.Remove the inner reel from the outer spool (Fig. 12).

3.Remove spring from the inner reel (Fig. 12).

4.Use a clean cloth to clean the the inner reel, spring, shaft, and inner surface of the outer spool.

5.Check the indexing teeth on the inner reel and outer spool for wear (Fig. 13). If necessary, remove burrs or replace the reel and spool.

Outer Spool

Spring

Inner Reel

Fig. 12

Indexing Teeth

Fig. 13

NOTE: SplitLine™ can only be used with the inner reel with the slotted holes. Single line can be used on either type of inner reel. Use Figure 14 to identify the inner reel you have.

NOTE: Always use the correct line length when installing trimming line on the unit. The line may not release properly if the line is too long.

For Use with Single

For Use with SplitLine™

Line ONLY

or Single Line

 

Slotted

 

Holes

Fig. 14