5.Remove the knob from the pin. Make sure that the collar and the spring are on the pin.

Press the Latch Insert (77) into the right side of the left Upright (85), and press the Knob Insert (92) into the left side of the left Upright. Use a rubber mallet, if necessary. Next, insert the pin into the Latch Insert, and tighten the knob back onto the pin.

5

 

Knob

77

 

92

Spring

 

 

Collar

85

Pin

6.Make sure that all parts are properly tightened before you use the treadmill. Keep the included allen wrench in a secure place; the allen wrench is used to adjust the walking belt (see page 26). To protect the floor or carpet from damage, place a mat under the treadmill.

If you purchase the optional chest pulse sensor (see page 22), follow the steps below to install the re- ceiver included with the chest pulse sensor.

1.Make sure that the power cord is unplugged. Remove the indicated Screw (7) and the Access Door (95) from the left side of the Console Back (98).

2.Connect the wire on the receiver (A) to the indicated wire extending from the Console Back (98). Hold the re- ceiver so the small cylinder is oriented as shown and is facing the Console Back. Attach the receiver to the plastic posts on the Access Door (95) with the two in- cluded small screws.

3.Make sure that no wires are pinched. Reattach the Access Door (95) with the Screw (7). Discard the other wires included with the receiver.

98

Wire

 

 

Small

 

Screws

95

 

 

A

 

Small

7

Cylinder

8

Page 8
Image 8