Nordyne 707831C E2 AireCare TM Electronic Air Filter, Installation Instructions 5 Ton A/C, Frame

Models: 707831C

1 4
Download 4 pages 24.46 Kb
Page 3
Image 3
E2 AireCare TM Electronic Air Filter

E2 AireCare TM Electronic Air Filter

Installation Instructions

(5 Ton A/C)

Before starting this installation, make sure that all electrical power to the furnace has been disconnected.

The 5 Ton E2 AireCare TM ElectronicAir Filter kit consists of a through the wall grille and frame kit and the electronic air filter with power cable.

Install Frame

1.Cut a rough-in opening (20" wide by 30" high) in the door or wall enclosing the E2 furnace.

2.Mount the frame kit into the opening using screw or wall board anchors.

Connect the AireCare TM

Electronic Air Filter

1.Connectthe electronicairfilterpowerwires

(24 VAC) to the red and gray (or black) low voltage terminals (R and C). Run this wire from the E2 furnace to the electronic air filter and frame. Connect the power wire marked with a white stripe or dash to C, the other to R.

2.Place the electronic air filter into the frame and connect the filter power cable by plug- ging it into the connector located at the top of the electronic air filter.

3.Turn on power to the furnace. The AireCare TM Electronic Air Filter is active if the light on top of the electronic air filter is lit.

4.Coverelectronicairfilterwith supplied grille.

Electronic

Filter

Air Filter

Frame

E2 Grille

E2 Frame

Figure 1. E2 Bracket installation