BLOWER PERFORMANCE - FG7TA/TK

FG7TA/TK - 80% AFUE, Two Stage Gas Furnace

 

Heating

Motor Switch

 

 

 

 

 

External Static Pressure (in.w.c.)

 

 

 

 

 

Model Number

Input

 

Setting

 

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

 

 

 

 

 

(Btuh)

1/5

2/6

3/7

4/8

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

0

0

600

74

555

80

510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

0

0

705

63

670

66

635

 

70

600

74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

1

0

775

57

740

60

705

 

63

665

67

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

1

0

900

49

870

51

835

 

53

800

56

765

58

730

61

695

64

660

67

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

1

0

950

47

920

48

890

 

50

855

52

825

54

795

56

765

58

730

61

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*TA/TK-060(C)-*A1

60000

1

1

1

0

1000

44

970

46

940

 

47

910

49

880

51

850

52

820

54

790

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

1

1075

41

1045

43

1015

 

44

985

45

960

46

925

48

900

49

870

51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

0

1

1110

40

1080

41

1055

 

42

1025

43

1000

44

975

46

945

47

920

48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

0

1

1170

38

1140

39

1115

 

40

1090

41

1060

42

1035

43

1010

44

985

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

0

1

1210

37

1185

38

1160

 

38

1130

39

1105

40

1080

41

1055

42

1025

43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

1

1

1520

29

1225

36

1200

 

37

1175

38

1150

39

1120

40

1095

41

1070

42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

1

1

1305

34

1280

35

1255

 

35

1230

36

1205

37

1180

38

1155

38

1130

39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

1

1

1350

33

1230

36

1305

 

34

1285

35

1260

35

1240

36

1215

37

1195

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

1

1440

31

1400

32

1365

 

33

1230

36

1295

36

1255

35

1220

36

1185

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

0

0

725

82

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

1

0

810

73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

1

0

940

63

890

67

845

 

70

795

75

750

79

700

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

1

0

990

60

945

63

905

 

65

860

69

820

72

775

76

735

81

690

86

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*TA/TK-080(C)-*B1

80000

1

1

1

0

1055

56

1015

58

970

 

61

930

64

890

67

845

70

805

74

760

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

1

1135

52

1095

54

1055

 

56

1010

59

960

62

930

64

890

67

850

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

0

1

1185

50

1145

52

1105

 

54

1065

56

1030

58

990

60

950

62

910

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

0

1

1250

47

1210

49

1170

 

51

1135

52

1095

54

1055

56

1020

58

980

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

0

1

1290

46

1255

47

1220

 

49

1180

50

1145

52

1110

53

1075

55

1040

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

1

1

1315

45

1275

46

1240

 

48

1200

49

1160

51

1120

53

1085

55

1045

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

1

1

1350

44

1315

45

1280

 

46

1245

48

1205

49

1170

51

1135

52

1100

54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

1

1

1390

43

1350

44

1315

 

45

1275

46

1240

48

1200

49

1160

51

1125

53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

1

1420

42

1380

43

1345

 

44

1310

45

1270

47

1235

48

1200

49

1160

51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.

2.Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.

3.Data is shown without filter.

4.Temperature rises in the table are approximate. Actual temperature rises may vary.

5.Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.

4

Page 4
Image 4
Nordyne warranty Blower Performance FG7TA/TK

FG7T specifications

The Nordyne FG7T is a highly efficient, gas-powered furnace designed to provide reliable heating for residential spaces. Known for its advanced technology and superior performance, the FG7T showcases Nordyne’s commitment to quality and innovation in home comfort systems.

One of the main features of the FG7T is its two-stage heating operation. This design allows the furnace to operate at two different heating intensities. In milder temperatures, it runs at a lower capacity, which maximizes energy efficiency and provides a comfortable environment without unnecessary energy consumption. During colder weather, the furnace can shift to high capacity for quick and effective heating.

Efficiency is a hallmark of the FG7T, with an impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 96%. This high AFUE rating means that a significant portion of the fuel is converted into usable heat, resulting in reduced energy costs and minimized environmental impact. With its highly efficient operation, homeowners can enjoy lower monthly utility bills while maintaining a warm and cozy atmosphere within their homes.

The FG7T is also equipped with a robust, durable heat exchanger, which is designed for longevity and reliable performance. The heat exchanger is made from high-quality materials that resist corrosion, extending the life of the furnace and ensuring dependable heating over the years. Additionally, the unit features a quiet operation, thanks to its well-engineered distribution system and low-noise blower motor, allowing for no disruption to daily activities.

Another notable feature is the integrated control system, which enhances user experience by allowing for easy temperature adjustments and diagnostics. This system provides homeowners with advanced monitoring capabilities, enabling them to maintain optimal performance and identify potential issues before they escalate.

Installation and maintenance of the Nordyne FG7T are straightforward, making it a practical choice for homeowners and professionals alike. With its compact design, the furnace can fit into many existing spaces without extensive modifications.

In summary, the Nordyne FG7T gas furnace is a powerful, efficient, and user-friendly heating solution. Boasting advanced features like two-stage heating, high efficiency, durable construction, and smart controls, it embodies the principles of comfort and sustainability. This makes it a solid investment for anyone looking to enhance their home’s heating system while being mindful of energy use and costs.