BLOWER PERFORMANCE - FG7TA/TK Continued

FG7TA/TK - 80% AFUE, Two Stage Gas Furnace

 

Heating

Motor Switch

 

 

 

 

External Static Pressure (in.w.c.)

 

 

 

 

 

Model Number

Input

 

Setting

 

0.1

 

0.2

 

0.3

 

0.4

 

0.5

 

0.6

 

0.7

 

0.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Btuh)

1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

1125

79

1040

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

0

0

1205

74

1120

79

1040

85

 

 

 

 

 

 

 

 

 

 

 

 

0

1

0

0

1305

68

1225

73

1150

77

1070

83

 

 

 

 

 

 

 

 

 

 

1

1

0

0

1430

62

1350

66

1270

70

1190

75

1110

80

1030

86

 

 

 

 

 

 

0

0

1

0

1525

58

1450

61

1375

65

1300

68

1225

73

1150

77

1075

83

1000

89

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

1

0

1620

55

1540

58

1465

61

1390

64

1315

68

1240

72

1165

76

1090

82

01 1 0 1695 52 1620 55 1545 58 1465 61 1390 64 1315 68 1235 72 1160 77

*TA/TK-120(C )-*C1 120000

1

1

1

0

1770

50

1700

52

1630

55

1555

57

1485

60

1410

63

1340

66

1265

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

1

1875

47

1805

49

1730

51

1655

54

1580

56

1510

59

1435

62

1340

66

 

1

0

0

1

1905

47

1840

48

1775

50

1710

52

1640

54

1575

56

1510

59

1445

62

 

0

1

0

1

1980

45

1910

47

1845

48

1780

50

1715

52

1650

54

1580

56

1515

59

 

1

1

0

1

2025

44

1960

45

1895

47

1830

49

1765

50

1700

52

1635

54

1570

57

0

0

1

1

2085

43

2025

44

1960

45

1900

47

1840

48

1775

50

1715

52

1655

54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

1

1

2135

42

2070

43

2010

44

1945

46

1880

47

1815

49

1750

51

1685

53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

1

1

2200

40

2145

41

2090

43

2035

44

1980

45

1925

46

1870

48

1820

49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

1

2280

39

2225

40

2170

41

2115

42

2065

43

2010

44

1955

45

1900

47

0

0

0

0

1395

74

1350

77

1305

79

1260

82

1210

86

1165

89

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

0

0

1465

71

1420

73

1375

75

1330

78

1290

80

1245

83

1200

86

 

 

 

0

1

0

0

1555

67

1510

69

1470

71

1425

73

1380

75

1340

77

1295

80

1250

83

 

1

1

0

0

1625

64

1585

65

1540

67

1500

69

1460

71

1415

73

1375

75

1335

78

 

0

0

1

0

1690

61

1650

63

1610

64

1570

66

1530

68

1485

70

1445

72

1405

74

1

0

1

0

1760

59

1715

60

1670

62

1625

64

1575

66

1530

68

1485

70

1440

72

01 1 0 1835 57 1790 58 1745 59 1695 61 1650 63 1605 65 1555 67 1510 69

*TA/TK-140(C)-*D1 140000

1

1

1

0

1885

55

1840

56

1790

58

1745

59

1700

61

1655

63

1610

64

1565

66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

1

1945

53

1900

55

1850

56

1805

57

1760

59

1710

61

1665

62

1620

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

0

1

1950

53

1905

54

1860

56

1820

57

1775

58

1735

60

1690

61

1650

63

 

0

1

0

1

2075

50

2030

51

1990

52

1945

53

1900

55

1855

56

1810

57

1770

59

 

1

1

0

1

2125

49

2085

50

2040

51

2000

52

1955

53

1910

54

1870

55

1825

57

 

0

0

1

1

2170

48

2130

49

2090

50

2045

51

2005

52

1965

53

1925

54

1880

55

1

0

1

1

2215

47

2180

48

2140

48

2105

49

2070

50

2035

51

2000

52

1965

53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

1

1

 

 

 

 

 

 

 

 

2225

47

2165

48

2100

49

2040

51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

1

 

 

 

 

 

 

 

 

 

 

2170

48

2120

49

2065

50

Notes:

1.Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.

2.Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.

3.Data is shown without filter.

4.Temperature rises in the table are approximate. Actual temperature rises may vary.

5.Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.

6

Page 6
Image 6
Nordyne warranty Blower Performance FG7TA/TK

FG7T specifications

The Nordyne FG7T is a highly efficient, gas-powered furnace designed to provide reliable heating for residential spaces. Known for its advanced technology and superior performance, the FG7T showcases Nordyne’s commitment to quality and innovation in home comfort systems.

One of the main features of the FG7T is its two-stage heating operation. This design allows the furnace to operate at two different heating intensities. In milder temperatures, it runs at a lower capacity, which maximizes energy efficiency and provides a comfortable environment without unnecessary energy consumption. During colder weather, the furnace can shift to high capacity for quick and effective heating.

Efficiency is a hallmark of the FG7T, with an impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 96%. This high AFUE rating means that a significant portion of the fuel is converted into usable heat, resulting in reduced energy costs and minimized environmental impact. With its highly efficient operation, homeowners can enjoy lower monthly utility bills while maintaining a warm and cozy atmosphere within their homes.

The FG7T is also equipped with a robust, durable heat exchanger, which is designed for longevity and reliable performance. The heat exchanger is made from high-quality materials that resist corrosion, extending the life of the furnace and ensuring dependable heating over the years. Additionally, the unit features a quiet operation, thanks to its well-engineered distribution system and low-noise blower motor, allowing for no disruption to daily activities.

Another notable feature is the integrated control system, which enhances user experience by allowing for easy temperature adjustments and diagnostics. This system provides homeowners with advanced monitoring capabilities, enabling them to maintain optimal performance and identify potential issues before they escalate.

Installation and maintenance of the Nordyne FG7T are straightforward, making it a practical choice for homeowners and professionals alike. With its compact design, the furnace can fit into many existing spaces without extensive modifications.

In summary, the Nordyne FG7T gas furnace is a powerful, efficient, and user-friendly heating solution. Boasting advanced features like two-stage heating, high efficiency, durable construction, and smart controls, it embodies the principles of comfort and sustainability. This makes it a solid investment for anyone looking to enhance their home’s heating system while being mindful of energy use and costs.