Nordyne FG7T warranty Specifications, Model Identification Code, FG 7 T A 080 C 23 B

Models: FG7T

1 8
Download 8 pages 29.6 Kb
Page 7
Image 7
MODEL IDENTIFICATION CODE

MODEL IDENTIFICATION CODE

FG 7 T A 080 C 23 B 1

Gas Furnace

Design Series

S = Single Stage

T = Two Stage

M = Modulating

A = 80% Upflow/Horizontal

C = 92.1% / 95.1% Upflow/Horizontal

K = 80% Downflow

L = 92.1% / 95.1% Downflow

Q = 96.4+% AFUE Upflow/Horizontal

Input Heating Capacity 060 = 60,000 080 = 80,000

100 = 100,000

120 = 120,000

140 = 140,000

Revision Level

Cabinet Width

A = 14.25

B = 17.50

C = 21.00

D = 24.50

Cooling Airflow

23 = 2-3 Tons

24 = 2-4 Tons

35 = 3-5 Tons

45 = 4-5 Tons

V = VSB

C = Standard

D = 90+% AFUE Low NOx

SPECIFICATIONS

FG7TA/TK

 

 

 

 

 

 

MODEL NUMBERS

060C-23A1

080C-24B1

100C-24B1

100C-35C1

120C-35C1

140C-45D1

Input - Btuh (a)

60,000 / 39,000

80,000 / 52,000

100,000 / 65,000

100,000 / 65,000

120,000 / 78,000

140,000 / 91,000

Heating Capacity - Btuh

48,000 / 31,200

64,000 / 41,600

80,000 / 52,000

80,000 / 52,000

96,000 / 62,400

112,000 / 72,800

 

 

 

 

 

 

 

AFUE

80.0

80.0

80.0

80.0

80.0

80.0

Blower D x W

10 x 6

11 x 8

11 x 8

11 x 10

11 x 10

11 x 10

 

 

 

 

 

 

 

Motor H.P. - Speed - Type

1/2 - BLDC

1/2 - BLDC

3/4 - BLDC

3/4 - BLDC

3/4 - BLDC

1 - BLDC

 

 

 

 

 

 

 

Motor FLA

6.2

6.2

8.7

8.7

8.7

11.7

Rated Ext. SP - In. W.C.

0.5

0.5

0.5

0.5

0.5

0.5

 

 

 

 

 

 

 

Temperature Rise Range - ºF

25-55

30-60

30-60

35-65

35-65

40-70

Shipping Weights

115lbs

110lbs

120lbs

125lbs

135lbs

155lbs

All models are 115 V, 60 HZ. Gas connections are 1/2" N.P.T.

AFUE= Annual Fuel Utilization Efficiency

7

Page 7
Image 7
Nordyne FG7T warranty Specifications, Model Identification Code, FG 7 T A 080 C 23 B