Nortel Networks NN43021-110 manual System options, CS 1000M HGand Meridian 1 Option 51C

Models: NN43021-110

1 70
Download 70 pages 60.03 Kb
Page 15
Image 15

System options 15

System options

This document includes information on the following Large Systems:

CS 1000M HGand Meridian 1 Option 51C: enhanced common control complex, single CPU, and one half network group

CS 1000M SG, Meridian 1 PBX 61C CP PIV, and Meridian 1 Option 61C: enhanced common control complex, dual CPU, and one full-network group

CS 1000M MG, Meridian 1 PBX 81C CP PIV, Meridian 1 Option 81, and Meridian 1 Option 81C: enhanced common control complex, dual CPU, and multiple-network groups

These systems are available in AC- and DC-powered versions.

CS 1000M HGand Meridian 1 Option 51C

The CS 1000M HGand the Meridian 1 Option 51C are single-CPU systems with a half-network group. One Core/Network module and one IPE module are required. Additional IPE modules, Remote IPE modules, and application modules can be used.

Table 2 "Specifications for CS 1000M HGand Meridian 1 Option 51C" (page 17) lists the specifications for these systems. Figure 1 "Meridian 1 Option 51C" (page 16) illustrates an Option 51C system.

With the addition of a Signaling Server, Meridian 1 Option 51C becomes a CS 1000M HG. Figure 2 "CS 1000M HG" (page 16) on Figure 2 "CS 1000M HG" (page 16) illustrates a CS 1000M HG.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Large System Overview

NN43021-110 02.05 Standard

30 September 2008

Copyright © 2003-2008 Nortel Networks