Nortel Networks NN43021-110 manual CS 1000M MGand Meridian 1 PBX 81C CP PIV

Models: NN43021-110

1 70
Download 70 pages 60.03 Kb
Page 21
Image 21

System options 21

CS 1000M MGand Meridian 1 PBX 81C CP PIV

The CS 1000M MGand Meridian 1 PBX 81Care dual-CPU systems with standby processing capabilities, fully-redundant memory, and up to eight full network groups. These systems are equipped with two redundant input/output processor and disk drive unit combination packs.

The following modules are required:

two Core/Network modules (provides one network group)

a minimum of two Network modules (provides one network group)

a minimum of one IPE module

Additional Network and IPE modules are required for additional network groups. Application modules can also be used.

Figure 5 "Meridian 1 PBX 81C CP PIVor Option 81C" (page 21) shows a typical configuration for eight full network groups. Additional columns can be added, and there can be more than one row of columns.

With the addition of a Signaling Server, Meridian 1 Option 81C or Meridian 1 PBX 81C CP PIVbecomes a CS 1000M MG. Figure 6 "CS 1000M MG" (page 22) illustrates the CS 1000M MG.

Figure 5

Meridian 1 PBX 81C CP PIVor Option 81C

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Large System Overview

NN43021-110 02.05 Standard

30 September 2008

Copyright © 2003-2008 Nortel Networks

Page 21
Image 21
Nortel Networks NN43021-110 manual CS 1000M MGand Meridian 1 PBX 81C CP PIV, Meridian 1 PBX 81C CP PIVor Option 81C