System options 17
Table 2
Specifications for CS 1000M HGand Meridian 1 Option 51C
System characteristics: |
|
|
Maximum number of ports | • | 1000 |
Input voltage | • | 208 V AC or |
Number of CPUs | • | 1 |
Number of network loops | • | 16 |
Memory options: |
|
|
Release 25 | • | NT5D10 CP or NT5D03 CP card |
Succession 3.0 | • | CP3 NT5D10 CP or CP4 NT5D03 card |
CS 1000 Release 4.5 | • | CP3 NT5D10 CP or CP4 NT5D03 card |
Software generic | • | 2811 |
Base hardware: |
|
|
Core/Network module | Required per system: | |
| • | |
| Required per module: | |
| • CE power supply (CEPS) | |
| • Call Processor (CP) card | |
| • Input/Output Disk Unit with | |
| • Core to Network Interface (cCNI) card | |
| • | |
| • Clock Controller Card (MCLK) | |
IPE module | • | IPE power supply |
| • | IPE cards |
Pedestal (one per column) | • | System Monitor |
| • | PDU |
| • | Blower unit |
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
30 September 2008