16Power supply installation

Note the following information:

If a power supply fails when you have a redundant power supply installed, the Ethernet Routing Switch 8300 continues to operate with no interruption of service. The chassis will continue to supply the same module and PoE output power with the remaining power supplies. A trap and syslog message will indicate that the configuration is non-redundant.

Nortel recommends that you operate the Ethernet Routing Switch 8300 in a redundant configuration at all times to ensure maximum network up time.

Nortel recommends that you install each power supply on its own dedicated branch circuit. When you plug the power cord for each power supply into a separate AC circuit, the redundant power supply also provides protection against the disconnection or failure of an individual branch circuit or power supply failure.

If you have installed a redundant power supply, power available for PoE is always determined on an N+1 redundancy. If you have 1 or 2 power supplies in the chassis, you will be allocated PoE power equivalent to one power supply. If you have 3 power supplies in the chassis, you will be allocated PoE power equivalent to 2 power supplies.

Table 4

8306/8310 chassis available system power

 

 

Number

 

 

 

 

 

Power

Power supply

of

Redundancy

Module

PoE

Fans

Total

Supply

rating

power

 

 

 

 

 

 

 

supplies

 

 

 

 

 

 

 

 

 

 

 

 

 

8301AC

100-120VAC

1

No

600 W

450 W

90 W

1140 W

 

 

 

 

 

 

 

 

 

 

2

Yes 1+1

600 W

450 W

90 W

1140 W

 

 

 

 

 

 

 

 

 

1140W

3

Yes 2+1

1290 W

900 W

90 W

2280 W

 

 

 

 

 

 

 

 

 

200-240VAC

1

No

780 W

900 W

90 W

1770 W

 

 

 

 

 

 

 

 

 

 

2

Yes 1+1

780 W

900 W

90 W

1770 W

 

 

 

 

 

 

 

 

 

1770W

3

Yes 2+1

1650 W

1800 W

90 W

3540 W

 

 

 

 

 

 

 

 

8302AC

100-120VAC

1

No

535 W

225 W

90 W

850 W

 

 

 

 

 

 

 

 

 

 

2

Yes 1+1

535 W

225 W

90 W

850 W

 

 

 

 

 

 

 

 

 

850W

3

Yes 2+1

1160 W

450 W

90 W

1700 W

 

 

 

 

 

 

 

 

 

200-240VAC

1

No

860 W

450 W

90 W

1400 W

 

 

 

 

 

 

 

 

 

 

2

Yes 1+1

860 W

450 W

90 W

1400 W

 

 

 

 

 

 

 

 

 

1400W

3

Yes 2+1

1810 W

900 W

90 W

2800 W

 

 

 

 

 

 

 

 

Nortel Ethernet Routing Switch 8300

Installation — AC Power Supply

NN46200-301 03.01 Standard

4.027 August 2007

Copyright © 2007, Nortel Networks

Page 16
Image 16